170
SX-15CCZA Hydrocarbon Hydronic Heating Air Sourced Heat Pump
For heating up to about 120sqm floorspace for panel radiators
For heating up to about 150sqm floorspace for concrete slab heating
Our SX-15CCZA Hydrocarbon Hydronics Heat Pump is not an "off-the-shelf" import, it is unique and purpose-built to heat water for hydronic heating systems.
The cabinet and refrigeration system is pre-assembled to our design.
We finish them locally,install our control system, charge them with Hydrocarbons, then fine-tune and put each heat pump through quality assurance testing.
Over the years we have developed our own inhouse heatpump tuning/monitoring rig.
Every machine that leaves our factory has been fine-tuned for its application, has been "run-in" for hours, and is shipped with its own performance guarantee.
When it is delivered and installed, it will work faultlessly from day one.
The SX-15CCZA can heat water to a maximum of 55oC
(recommend design for 55/45oC for new radiator installations
|
 |
|
See below for tips on sizing your heatpump for
MAXIMUM EFFICIENCY AND SERVICE LIFE!
Technical data:
- Nominal input power: 2.2kW - 3.6kW
- Voltage: 220V
- Pipe size: DN25
- Max outlet water temp: 55oC
- Environment range: -19oC to +45oC
- Compressor: 3.5HP Copeland ZR42K3E-PFJ-522 scroll
- Refrigerant: Hydrocarbons
- Fans: 2x Zeihl Abegg FN045-6EK.4F.V79P1
450mm, 190W, 67m3/min airflow (each)
- Weight: 160Kg
- Dimension: 1120x650x1270mm
- Warranty: 3yrs *for all systems delivered after Jan 2017
Subject to suppliers sizing and installation guidelines being followed
*(there may be a travel charge for on-site service if there is a significant distance)
Download SX-15CCZA data sheet
|
We use Natural Organic hydrocarbons:
Our hydronic heat pumps use hydrocarbon instead of traditional refrigerant, a highly efficient blend of R290 and R170, propane and ethane. When switching from R22, R502, R407C, and R404A power bills can be dramatically reduced, and the wear and tear on the refrigeration system can also be minimised.
It's the Natural Organic solution
ZA Hi-Tech Low Noise Owlet axial fans:
Improved airflow and up to 15% higher fan efficiency
Especially for installations where noise could be an issue, we recommend using the ZA model with super-efficient low-noise Ziehl-Abegg "Owlet" axial fans.
 |
Specifications are subject to change without notice
RRP $8,200* incl GST for ZA model with low-noise Ziehl-Abegg "Owlet" fans
plus delivery & installation * prices are subject to change without notice, so
please call
for latest pricing - special promotions etc.
We welcome trade enquiries! - 1300 552 976
Recommended Primary Circulation Pump for SX-15CCZA
We offer a small range of circulating pumps to suit a variety
of applications.
An essential part of any hydronic heating system is the circulating
pump or pumps.
The following table lists a range of circ. pumps to compliment
our Air Sourced Hydronic Heat Pumps as primary circuit pump
between the heat pump and the buffertank, and as the 'zone'
pump(s) which circulate the water between the buffertank and
the floorcoils and/or radiator panels.
The primary circulation pump must be matched to the flow-rate
required by the heat pump.
The secondary or zone pumps are usually 0.5 to 1.5 Litres
per second.
Some of our circulating pumps have 3 speeds to allow for varying
conditions:
|
Model |
Body |
Speed |
Conn's |
Head |
Watts |
Flow Rate |
R.R.P. |
Comment |
>GPD25-6< |
C.I. |
3 sp |
25mm |
2.5m |
100/70/55 |
1.0L/s@1.8m |
|
hydronics zone pump |
|
>GPD25-8< |
C.I. |
3 sp |
25mm |
8m |
245 |
1.4L/s@5m |
|
hydronics single-zone pump |
|
>GPD32-9< |
C.I. |
1 sp |
32mm |
5m |
300 |
1.6L/s@5m |
|
SX-15CCZA (close-coupled buffertank) |
>GPD25-16< |
C.I. |
1 sp |
32mm |
12.5m |
700 |
2.5L/s@5m |
|
SX-15CCZA primary pump (remote buffertank) |
Skyline Energy stainless steel buffertanks
With the SX-15CCZA we recommend using a 100Lt or 200Lt buffertank.
Installing a buffertank on a hydronic heat-pump allows for zoning without causing backpressure or flow-rate fluctuations which may trip the heat-pump.
Hydronic Buffertanks also reduce short-cycling which increases efficiency.
With a heat-pump hydronic system, heat energy is always readily available so a larger buffertank is not necessary and in fact can reduce efficiency. (one reason why we don't recommend multiple potable hot water heat-pumps for hydronics)
|
 |
Other Models:
Simplified rules for sizing your heatpump for hydronic heating
- for MAXIMUM EFFICIENCY AND SERVICE LIFE!
- Calculate how many kW are required
- Look at the climatology of the location to establish the duration of 0oC to +4oC. Don’t just look at the extreme temps, look at the mean overnight temp and duration
- If the ambient air temp rarely dips below +4oC or does so for short periods then you can use this simple calculation...
3.3 x electricity input kW = heatpump output heat kW to size the heatpump.
- If the mean overnight ambient air temp is between 0oC and +4oC change the calculation to
2.2 x electricity input kW = heatpump output heat kW to size the heatpump.
- A more powerful heatpump will raise the water temp more rapidly so it will cycle off before it needs to defrost, thereby maintaining a higher COP and efficiency.
- Warranty service may be refused if our sizing guidelines are ignored.
|
MODEL |
POWER |
COMPRESSOR |
AIR DISCHARGE |
5 STAR CAPABILITY |
|
|
QTY |
Brand Model |
|
(5 star energy construction rating) |
220V 1ph |
>> SX-06 |
220V, 1ph |
1x |
Mitsubishi Rotary RN145V, 1.0HP |
1x fan - side |
up to 48sqm radiators or 60sqm slab |
>> SX-08 |
220V, 1ph |
1x |
Mitsubishi Rotary RN222VHFMC, 2.5HP |
1x fan - side |
up to 67sqm radiators or 85sqm slab |
>> SX-11CCZA |
220V, 1ph |
1x |
Copeland ZR28K3E-PFJ-522, 2.33HP
|
2x fan - side |
up to 90sqm radiators or 110sqm slab |
>> SX-13CCZA |
220V, 1ph |
1x |
Copeland ZR34K3E-PFJ-522, 2.83HP
|
2x fan - side |
up to 100sqm radiators or 130sqm slab |
>> SX-15CCZA |
220V, 1ph |
1x |
Copeland ZR42K3E-PFJ-522, 3.5HP
|
2x fan - side |
up to 120sqm radiators or 150sqm slab |
>> SX-17CCZA |
220V, 1ph |
1x |
Copeland ZR47K3E-PFJ-522, 4.0HP
|
2x fan - side |
up to 140sqm radiators or 170sqm slab |
>> SX-18ZA |
220V, 1ph |
1x |
Copeland ZW52KAE-PFS-522, 4.5HP |
2x fan - side |
up to 180sqm slab only (non frost area) |
>> SX-19ZA |
220V, 1ph |
1x |
Copeland ZR61KC-PFZ-522, 5.0HP |
2x fan - side |
up to 190sqm slab only (non frost area) |
|
|
|
|
|
|
220V 1ph or 2ph |
>> SX-20BZA |
220V 1 or 2ph |
2x |
Copeland ZR28K3E-PFJ-522, 2.33HP
|
2x fan - top |
up to 160sqm radiators or 200sqm slab |
>> SX-24ZA |
220V 1 or 2ph |
2x |
Copeland ZR34K3E-PFJ-522, 2.83HP
|
2x fan - top |
up to 200sqm radiators or 240sqm slab |
V-Models are recommended for heavy frost-prone areas |
>> V20ZA |
220V, 1 or 2ph |
2x |
Copeland ZR28K3E-PFJ-522, 2.33HP |
2x fan - V evap, top |
up to 160sqm radiators or 200sqm slab |
>> V25ZA |
220V 1 or 2ph |
2x |
Copeland ZR34K3E-PFJ-522, 2.83HP
|
2x fan - V evap, top |
up to 210sqm radiators or 250sqm slab |
>> V30ZA |
220V 1 or 2ph |
2x |
Copeland ZR42K3E-PFJ-522, 3.5HP
|
2x fan - V evap, top |
up to 250sqm radiators or 300sqm slab |
>> V35ZA |
220V 1 or 2ph |
2x |
Copeland ZR47K3E-PFJ-522, 4.0HP
|
2x fan - V evap, top |
up to 300sqm radiators or 350sqm slab |
Can't find what you want - maybe we can build it for you - ASK!
Please call for trade pricing
For all enquiries, please call the national
number below
or email
NATIONAL DISTRIBUTION
CALL CENTRE:
1300 552 976
|